Engineering Modern Building Automation, BACnet Protocols & Cloud Telemetry
Bespoke software architecture, BTL-compliant protocol stacks, and secure edge-to-cloud integrations built for smart facilities.
120+
BAS Deployments Engineered
99.98%
Edge-to-Cloud Uptime SLA
18ms
Median BACnet COV Latency
40+
Vendor Device Profiles Supported
Full-Stack Building Automation Expertise
From silicon-level BACnet stacks to multi-tenant cloud platforms, Hexomation covers every layer of the smart building software stack — engineered for BTL compliance, ASHRAE 135 conformance, and enterprise-grade security.
Building Automation Systems (BAS)
Centralized HVAC, lighting, and BMS architectural software designed for unified facility management.
BACnet Protocol Engineering
Deep-expertise BACnet IP & MS/TP stack development ensuring BTL compliance and seamless interoperability.
BACnet/SC Implementation
Modern TLS 1.3 encrypted cybersecurity for building networks, eliminating BBMD and VPN complexities.
Modbus & Gateway Integration
High-performance fieldbus translation bridging Modbus (RTU/TCP) and legacy hardware into modern BAS networks.
Cloud & SaaS Platforms
Multi-tenant telemetry portals, real-time analytics, and enterprise remote management dashboards.
Custom Automation Software
Bespoke edge drivers, specialized REST/GraphQL API drivers, and custom automation middleware.
One Cloud Control Plane for Every Building in Your Portfolio
BAaaS.io unifies BACnet, Modbus, and vendor-proprietary telemetry into a single multi-tenant operating layer — so facility teams get real-time visibility and developers get clean REST/GraphQL APIs, without re-engineering the field network.
- Sub-second COV telemetry pipeline
- BACnet/SC virtual hub, zero BBMDs
- Offline-resilient edge-to-cloud sync
Building Automation & BACnet Engineering Questions
What is BACnet/SC and why does it matter for building automation?
BACnet Secure Connect (BACnet/SC) is the ASHRAE 135-2020 standard for TLS 1.3 encrypted BACnet communication over IP. Hexomation implements BACnet/SC hubs and nodes that eliminate legacy BBMD broadcast forwarding and site-to-site VPN tunnels, replacing them with certificate-based mutual authentication across facility networks.
Do you support both BACnet MS/TP and BACnet/IP in the same deployment?
Yes. Our protocol stacks bridge BACnet MS/TP field trunks (RS-485) with BACnet/IP backbones through purpose-built routers, preserving segmentation while exposing a single unified object model to your BAS or BAaaS.io tenant.
How does BAaaS.io differ from a traditional Niagara or JACE-based BAS?
BAaaS.io is a multi-tenant, cloud-native control plane: telemetry, alarms, and device discovery run centrally with elastic scaling, while edge gateways handle local BACnet/Modbus polling and offline queuing. It complements Niagara deployments via edge drivers rather than replacing existing JACE investments outright.
Can Hexomation integrate legacy Modbus RTU devices into a modern BAS?
Yes. We engineer Modbus RTU/TCP gateway translation layers that normalize register maps from legacy chillers, meters, and VFDs into standard BACnet objects, so older field hardware becomes visible in modern dashboards without a hardware rip-and-replace.